Skip to main content

Table 4 Regression Analysis of parameters on blood lead level in workers, unadjusted and adjusted smoking

From: Nerve excitability test and lead toxicity: a case-control study

  

Univariate analysis

Multivariate analysis

p value

R2 (adjusted R2)

Standardized β (95% CI)

p value

R2 (adjusted R2)

Standardized β (95% CI)

NCS

Distal latency (ms)

0.242

0.112 (0.038)

-0.335 (-0.927, 0.258)

0.216

0.225 (-0.120)

-0.431 (-1.163, 0.302)

MEP

Latency (ms)

0.176

0.147 (0.076)

0.384 (-0.197, 0.964)

0.305

0.195 (-0.163)

0.359 (-0.387, 1.106)

 

Peak response (mV)

0.187

0.140 (0.068)

0.374 (-0.209, 0.958)

0.321

0.370 (0.091)

0.307 (-0.353, 0.967)

NET

S1 (TEh 20–40 ms)

0.094

0.216 (0.151)

0.465 (-1.022, 0.092)

0.252

0.247 (-0.088)

-0.390 (-1.112, 0.331)

 

S3 (TEh 90–100 ms)

0.051

0.281 (0.221)

-0.530 (-1.063, 0.003)

0.237

0.482 (0.252)

-0.335 (-0.934, 0.263)

  1. The multivariate model adjusted age, gender and smoking