Table 1 Measured mercury vapor concentrations (mg/m 3 ) in ambient air during dental amalgam removal

From: Mercury vapour exposure during dental student training in amalgam removal

 

Suction and water spray

Suction only (no water spray)

No suction and no water spray

Arithmetic mean and standard deviation (μg/m3)

8.0 ± 3.7

142.0 ± 234.6

214 ± 226.4

Median (μg/m3)

8.0

68.01

117.02

Range (μg/m3)

4.0–19.0

14.0–999.0

34.0–796.0

  1. 1 Statistically significantly greater (p < 0.001) from Suction & Water.
  2. 2 Statistically significantly greater (p = 0.031) from Suction & Water.