Skip to main content

Table 4 Linear mixed effect model of exposure determinants for hydrogen sulphide index (IN) in sewage workers

From: Hydrogen sulphide exposure in waste water treatment

Factor

B

SE

eB

Intercept

5.02*

1.35

151.42

Job type:

 Inside big plants

−2.55

1.52

0.08

 Pump stations and small plants

−1.73

1.51

0.18

 Working on sewer network

0

0

1.00

 Collecting sewage from cesspools

0.42

1.46

1.52

Time of the year:

 Winter

0

0

1.00

 Spring

−2.49*

0.88

0.08

 Summer

−1.10

0.82

0.33

 Autumn

−1.36*

0.65

0.26

Place:

 Capital 1

−1.14

1.10

0.32

 Capital 2

0.07

1.22

1.07

 Capital 3

−2.80*

1.09

0.06

 City 1

−2.07*

1.00

0.13

 City 2

0

0

1.00

 Rural 1

−1.90

1.33

0.15

 Rural 2

−0.38

0.69

0.68

 Rural 3

0.57

0.90

1.77

Flushing

 No

−1.10*

0.47

0.33

 Some

−1.16*

0.45

0.31

 More than 3 timers or over 10 min

0

0

1.00

Random effects

Variance

  

 Within worker

1.83

  

 Between worker

< 0.000

  
  1. B regression coefficient, SE Standard error, eB Determinants for calculating GM for different operations of work
  2. *p < 0.05