Skip to main content

Table 2 Compound specific mass spectrometer conditions.

From: Method optimization and validation for the simultaneous determination of arachidonic acid metabolites in exhaled breath condensate by liquid chromatography-electrospray ionization tandem mass spectrometry

Analyte

Ret. time (min)

Precursor ion

Product ion

DP

FP

CE

CXP

8-iso-PGF 2alfa

12.3

353.2

309.2

-66

-310

-26

-17

11-β-PGF 2alfa

12.4

353.2

309.2

-66

-310

-26

-17

PGF 2alfa

12.7

353.2

309.2

-66

-310

-26

-17

PGE 2

13.0

351.2

315.2

-36

-170

-16

-15

PGD 2

13.4

351.2

315.2

-36

-170

-16

-15

13,14-dihydro-15-keto-PGE 2

13.9

351.2

333.3

-26

-150

-16

-15

13,14-dihydro-15-keto-PGD 2

14.4

351.2

333.3

-26

-150

-16

-15

LTE 4

14.5

438.2

333.2

-14

-70

-24

-17

Delta 12-PGJ 2

14.7

333.2

315.1

-36

-200

-12

-17

PGJ 2

14.8

333.2

315.1

-36

-200

-12

-17

LTB 4

15.3

335.2

195.2

-31

-150

-16

-15

15-desoxy-delta12,14-PGJ 2

16.2

315.1

271.1

-45

-210

-16

-15

  1. Declustering and Focusing Potential as well as Collision Potential are expressed in Volts (V)